This demo version will run for approximately 2 hours in configuration. If "Start Monitoring" is selected it will run for approximately 20 minutes. Both selections terminate without warning.
PeakHMI MODBUS Master/Slave Relay Ladder Logic-Demo Version 2.1 This demo version is limited on the number of external connections and the logic engine will execute for approximately 20 minutes and then stop requiring a restart of the program to execute logic.
Slave Simulators All slave simulators are in one installer. Select the simulator in the installer. PeakHMI MODBUS TCP/IP Slave Version 2.1 PeakHMI MODBUS Serial RTU Slave Version 2.1 PeakHMI Triconex TSAA (TCP) Slave Version 0.0.0.1 Beta
Demo projects The following projects show HMI basic graphic animations. Buttons, gauge, hide/show, move, fill, brush color, pen color, groups, etc. are used without any scripts. The RLL program simulates a pump, tank level and several values. See the included "readme" file for more information. Pump Tank Demo A This demo uses the PeakHMI and PeakHMI RLL programs. (MODBUS TCP/IP) |
|
Pump Tank Demo A_ML_1000 This demo uses PeakHMI and a AB MicroLogix 1000. (DF1) Pump Tank Demo AD This demo uses PeakHMI and a DirectLogic05. (Automation Direct, K-Sequence) Pump Tank Demo GE This demo uses PeakHMI and a GE Series 90 Micro. (SNP-X) Pump Tank Demo A_SLC This demo uses PeakHMI and a AB SLC 5/04. (DF1) Pump Tank Demo A_S7-200 This demo uses PeakHMI and a Siemens S7-200. Pump Tank Demo A_CL This demo uses PeakHMI and a AB ControlLogix. (Ethernet/IP) Pump Tank Demo A_FX1 This demo uses PeakHMI and a Mitsubishi FX1. |
| Project Name | Logic Engine/PLC | PeakHMI Version required | Hardware |
|---|---|---|---|
| Pump Tank Demo A | PeakHMI RLL | 1.8 or higher | None |
| Pump Tank Demo A_ML_1000 | AB MicroLogix 1000 | 1.8.2 or higher | Ind-Concepts ABS01 |
| Pump Tank Demo AD | DirectLogic 05 (K-Sequence) | 1.8.3 or higher | Ind-Concepts ADS05 |
| Pump Tank Demo GE | GE Series 90 Micro (SNP-X) | 1.8.3 or higher | Ind-Concepts GES06 |
| Pump Tank Demo A_SLC | AB SLC 5/04 | 1.8.3 or higher | SLC 5/04 with I/O |
| Pump Tank Demo A_S7-200 | Siemens S7-200 | 2.0 or higher | Ind-Concepts SS01 |
| Pump Tank Demo A_CL | AB ControlLogix | 2.0.0.1 or higher | ControlLogix with I/O |
| Pump Tank Demo A_FX1 | Mitsubishi FX1 | 2.3 or higher | Ind-Concepts MITS07 |
The projects with Ind-Concepts hardware have been configured to work with the trainers from Ind-Concepts.
Copyright @2008 Everest Software LLC All rights reserved. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.