PeakHMI Drivers
- A/B DF1 (Redundant - Hot
Standby)
- PLC5, SLC500, SLC 5/01 -
5/05, MicroLogix
- A/B Ethernet (Redundant
- Hot Standby)
- ControlLogix,
CompactLogix, FlexLogix
- RSLinx not
required
- No third
party driver required
- A/B Ethernet PCCC (Redundant - Hot
Standby)
- SLC, MicroLogix, SLC 5/05,
PLC5
- RSLinx not
required
- No third
party driver required
- Bacnet/IP (Redundant
- Hot Standby)
- Analog Input, Analog Output, Analog Value, Binary
Input, Binary Output,
- Binary Value, Loop, Multi State Input, Multi State
Output, Averaging,
- Multi State Value, Life Safety Point, Life Safety
Zone
- Read Property, Write Property
- DNP3
Master
- RS-232, RS-485 and TCP/IP
- Enron MODBUS
- RS-232 and TCP/IP
- All register types
- GE SNP-X (Redundant -
Hot Standby)
- All register types
- Long break or long
break free
- GE SRTP (Redundant -
Hot Standby)
- IDEC (OpenNet) (Redundant -
Hot Standby)
- Keyence PLC(Redundant -
Hot Standby)
- K-Sequence (Redundant -
Hot Standby)
- Automation Direct (DirectLogic,
Koyo)
- All register types
- Master-K LS/LG
Industrial Systems (Redundant - Hot Standby)
- Mewtocol-COM (Panasonic/Matsushita/Aromat/NAIS)
(Redundant - Hot Standby)
- Mitsubishi FX 0,1,2,3
(Redundant - Hot Standby)
- Bit, Word, Longword, Float
- Mitsubishi
Serial
(Redundant - Hot Standby)
- Protocol 3C, Format 1
or 4, Checksum or no checksum
- All register types
- Bit, Word, Longword, Float
- Mitsubishi
TCP/IP
(Redundant - Hot Standby)
- Protocol 3E
- All register types
- Bit, Word, Longword, Float
- MODBUS/J-Bus Serial
(RS-232/485) ASCII
- Master
- Bit, Float, String, Word
- MODBUS/J-Bus Serial
(RS-232) RTU
(Redundant - Hot Standby)
- Master
and Slave
- Bit, Float, String, Word
- MODBUS/J-Bus Serial
(RS-485) RTU
- Master
- Bit, Float, String, Word
- MODBUS/J-Bus TCP/IP
(Redundant - Hot Standby)
- Master and Slave
- Bit, Float, String, Word
- ODBC (Open Database Connectivity)
- All dynamic tag values output to unlimited
number of concurrent databases
- Can be the source for analog or digital process
variables from unlimited number of concurrent databases
- Omron
FINS (RS-232) (Redundant - Hot Standby)
- C, CV or
CS/CJ mode
- All register types
- Bit, Word, Longword, Float
- Omron
FINS (TCP and UDP) (Redundant - Hot Standby)
- C, CV or
CS/CJ mode
- All register types
- Bit, Word, Longword, Float, String
- Omron Hostlink/SYSMAC-WAY
(Redundant - Hot Standby)
- Bit, Word, Longword, Float
- Omni
flow computers (Enron MODBUS) RS-232 and TCP
- Siemens S7-200 (PPI) (Redundant -
Hot Standby)
- Inputs, Outputs,
Analog Inputs, Analog Outputs, Variable memory, Timers, Counters,
Special memory
- All data types -
bit, byte, word, double word, float, timer, counter, string
- Siemens S7-300/400 (MPI) (Redundant -
Hot Standby)
- Inputs, Outputs,
Internal memory, Timers, Counters
- All data types -
bit, byte, word, double word, float, timer, counter
- Siemens S7-300/400/1200 (TCP) (Redundant -
Hot Standby)
- Inputs, Outputs,
Internal memory, Timers, Counters, Data blocks
- All data types -
bit, byte, word, double word, float, timer, counter
- SNMP
(Simple Network Management Protocol) Version 1
- UDP
- Traps with logging
- GetRequest/SetRequest